Calibration services

Please note that all accelerometer prices are for single axis transducers. For bi-axial or tri-axial transducers add $170.

Absolute calibration

Absolute (Primary) calibration by reciprocity provides a measurement uncertainty of 0.5 % at 2 g and a reference frequency of 80, 100, or 160 Hz, as specified by the customer.

Calibration Service NumberPrice (Qty 1)Frequency RangeSystem Cal3Transverse SensitivityReport/ Certificate1Resonance Search2
CS120$60620 Hz to 10 kHzNoYesFull ReportYes
CS120H$83620 Hz to 20 kHzNoYesFull ReportYes
CS120L$8361 Hz to 10KHzNoYesFull ReportYes
CS120LH$9041 Hz to 20 kHzNoYesFull ReportYes
CS120S$94120 Hz to 10 KHzYesYesFull ReportYes
CS120LH-S$9931 Hz to 20 kHzYesYesFull ReportYes
CS120LS$9931 Hz to 10KHzYesYesFull ReportYes

 

Comparison calibration

Secondary calibration by comparison provides a measurement uncertainty of ± 1.2 % (100 Hz), ± 1.5 % (20 Hz to 2500 Hz), ± 2.5 % (>2500 Hz to 10 000 Hz), and 5 % (>10 000 Hz to 20 000 Hz).

Calibration Service NumberPrice (Qty 1)Frequency RangeSystem Cal3Transverse SensitivityReport/ Certificate1Sensor ManufacturerResonance Search2
CS130$31420 Hz to 10 kHzNoYesFull ReportEndevcoYes
CS130H$67420 Hz to 20 kHzNoYesFull ReportEndevcoYes
CS130L$6061 Hz to 10KHzNoYesFull ReportEndevcoYes
CS130LH$7841 Hz to 20 kHzNoYesFull ReportEndevcoYes
CS130S$62720 Hz to 10 kHzYesYesFull ReportEndevco/Non-EndevcoYes
CS130LH-S$7841 Hz to 20KHzYesYesFull ReportEndevcoYes
CS130LS$7321 Hz to 10KHzYesYesFull ReportEndevcoYes
CS130T4$60120 Hz to 10 kHzNoYesFull ReportEndevcoYes
CS135$28720 Hz to 10 kHzNoNoFull ReportEndevcoYes
CS135L$5281 Hz to 10KHzNoNoFull ReportEndevcoYes
CS135LH$5801 Hz to 20 kHzNoNoFull ReportEndevcoYes
CS410$25020 Hz to 10 kHzNoYesStandard CertEndevcoYes
CS415$25020 Hz to 10 kHzNoNoStandard CertEndevcoYes
CS410TEDS5$32420 Hz to 10 kHzNoYesStandard CertEndevcoYes
CS420$25020 Hz to 10 kHzNoYesStandard CertNon-EndevcoYes
CS425$25020 Hz to 10 kHzNoNoStandard CertNon –EndevcoYes
CS420L$2501 Hz to 10 kHzNoYesStandard CertNon-EndevcoYes
CS2106$38120 Hz to 10 kHzNoYesStandard CertEndevcoYes

 

Shock calibration

Half-sine shock calibration by comparison provides a measurement uncertainty of ± 1.9 % (20 to 2 000 g) and 2.7% (2 000 to 10 000 g).

Calibration Service NumberPrice (Qty 1)Shock rangeFrequency Range7System Cal3Transverse Sensitivity
CS110$49620g to 10Kg, 5 levels20 Hz to 10 kHzNoYes
CS110S$59620g to 10Kg, 5 levels20 Hz to 10 kHzYesYes
CS220$25220g to 10Kg, 5 levelsN/ANoYes
CS220S$25220g to 10Kg, 5 levelsN/AYesYes
CS111$78410Kg to 100Kg, 5 levelsN/ANoYes
CS115$73210Kg to 100Kg, 5 levelsN/ANoNo

 

Environmental calibration

Sensitivity calibration at temperature.

Calibration Service NumberPrice (Qty 1)DescriptionTemp Range °C (°F)Transverse Sensitivity
CS310$319Sensitivity measurement at single frequency, at customer specified temperature-55 to +175 (-67 to +345)No
CS315$293Sensitivity measurement at single frequency, at customer specified temperature-55 to +175 (-67 to +345)Yes
CS330$935Sensitivity measurement at single frequency, at customer specified temperature-173 to +760 (280 to +1400)Customer specified
  1. Full report includes a 5+ page comprehensive report. Standard Cert includes a 1 page calibration certificate
  2. Resonance search is performed up to 50 000 Hz or the sensor’s highest specification frequency
  3. System cal performs the calibration procedure on the measurement systems including a transducer and its associated cable and signal conditioning
  4. For triaxial accelerometers
  5. Includes TEDS (Transducer Electronic Data Sheet) verification and update
  6. Amplitude linearity (5 g levels from 1 g to 100 g, specified by customer)
  7. Includes standard frequency sweep